WTI NPS-115 Guide de l'utilisateur Page 81

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 174
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 80
5-54
Basic Configuration
PlugGroupAccess: Determines the default Plug Group Access setting for
new TACACS users. For more information on Plug Groups, please refer to
Section 5.6. (Defaults; Administrator and SuperUser = All Plug Groups On,
User = All Plug Groups Off, ViewOnly = All Plug Groups Off.)
Notes:
In order to use this feature, you must first define at least one Plug Group as
described in Section 5.6.
Administrator and SuperUser level accounts will always have access to all
plug groups.
User Level accounts will only have access to the plug groups that are
defined via the Plug Group Access parameter.
ViewOnly accounts are not allowed to invoke switching and reboot
commands.
ServiceAccess: Selects the default Service Access setting for new TACACS
users. Determines whether each account will be able to access command mode
via Serial Port, Telnet/SSH or Web. In addition, the Service Access setting also
determines whether each account will be able to employ the Outbound Access
function. (Default = Serial Port = On, Telnet/SSH = On, Web = On, Outbound
Access = Off.)
Note: If Outbound Access has been disabled via the Network Parameters
menu, then the Service Access parameter will not be allowed to grant Outbound
Access to new TACACS users.
ServiceAccess: Selects the default Service Access setting for new TACACS
users. The Service Access setting determines whether each account will be able
to access command mode via Serial Port, Telnet/SSH or Web. For example,
if Telnet/SSH Access is disabled for an account, then the account will not be
able to access command mode via Telnet or SSH. (Default = Serial Port = On,
Telnet/SSH = On, Web = On.)
Current/PowerMetering: (VMR Only) Selects the default enable/disable
status for the Current/Power Metering setting. When Current/Power Metering is
disabled, an account will not be able to view current or power readings or display
current or power history. Note that in order for accounts to be able to display
these logs, Current and Power Metering must be enabled via the Systems
Parameters menu as described in Section 5.3. (Default = Off.)
Note: Current and Power Metering functions are not available on NPS units.
PingTest(PingTACACSServers): Allows you to ping IP addresses or domain
names that have been defined via the TACACS Parameters menus in order to check
that a valid IP address or domain name has been entered.
Notes:
In order for the Ping Test feature to function, your network and/or firewall
must be configured to allow ping commands.
In addition to the Ping Test feature, the /TEST command in the Text Interface
or the "Test" option in the Web Browser Interface can also be used to ping
any user defined IP address in order to make certain that the IP address is
responding.